Yokogawa
Confocal scanner with CSU-W1 rotating disk
Wide field confocal microscopy of living cells: field of view 17×16 mm, up to 200 frames / s
Yokogawa CSU-W1 is a wide-field confocal scanner for careful high-speed imaging of living cells, tissues and bulk biological samples.
Request a quotationNipkow's dual-rotating microlens drive forms a multi-point scan with low phototoxicity and fading. Motorized confocal and light-field switching, one- or two-camera options, and split-view allow you to assemble the system for time-lapse, multi-channel and deep imaging.
Field of view 17×16 mm; scanning frequency 75–200 Hz at 1500–4000 rpm Install up to two discs with pinholes of 50 or 25 μm; excitation 405–647 nm, optionally NIR 685–785 nm; registration 420–850 nm. T1, T2 and T3 versions, SoRa options, Uniformizer and external light path are available.
Speed and care
- Nipkow’s Microlensed Double Rotating Disc Reduces Phototoxicity and Fading During Long Shooting
- The disk rotation speed of 1500-4000 rpm gives a scanning frequency of 75-200 frames / s
- Motorized switching between confocal and light-field channels without changing optics
Flexibility of configuration
- Three basic configurations: one camera (T1), two cameras (T2) and split-view with one camera (T3)
- Selection of 50 or 25 microns pinhole discs for different contrast and resolution tasks
- Optional NIR port for 685-785 nm excitation and less invasive deep imaging
Extensibility
- Upgrade to SoRa superresolution (150 nm XY, 320 nm Z) without replacing the base unit
- External light port for photoactivation and connection of additional scanners
- All functions can be added after installation of the device.
Optical system
| Parameter | T1 (1 camera) | T2 (2 cameras) | T3 (Split-view) |
|---|---|---|---|
| Method of scanning | Microlensed two-disc scanning by Nipkow | ||
| Disc speed | 1,500–4,000 rpm (75–200 fps) | ||
| Pinhole discs | 50 μm and 25 μm, motorized shift, up to 2 discs simultaneously | ||
| Field of vision | 17x16 mm | ||
| Excitation wavelength | 405–647 nm; option NIR 685–785 nm | ||
| The wavelength of the registration | 420–850 nm |
Configuration T1 / T2 / T3
| Parameter | T1 (1 camera) | T2 (2 cameras) | T3 (Split-view) |
|---|---|---|---|
| Number of cameras | 1 | 2 | 1 (split-view) |
| Filter-wheel | 10-position | 10-position x2 | 6-position |
| Port of camera | C-mount, 0.83x or 1x | ||
| Mass of the main block | 18 kg | 21.5 kg | 19 kg |
| External dimensions | 480×327×252 mm | 480×476×252 mm | 374×425×252 mm |
General parameters
| Parameter | T1 (1 camera) | T2 (2 cameras) | T3 (Split-view) |
|---|---|---|---|
| External synchronization | TTL, 300-800 Hz | ||
| Working environment | 15–35 °C, 20–75% without condensation | ||
| Power supply | 100–240 V alternate current, 50/60 Hz, no more than 250 VA | ||
| Controls | RS-232C (compatible with CSU-X1) commands |
SoRa (option)
| Parameter | T1 (1 camera) | T2 (2 cameras) | T3 (Split-view) |
|---|---|---|---|
| Superresolution method | Optical Reassignment (SoRa) | ||
| Optical resolution | XY 150 nm, Z 320 nm | ||
| Switching the increase | motorized, 3 positions, less than 5 seconds |