Xian Tianlong
Automatic extraction workstation NC PANA9600X
Complete cycle from closed primary tube to finished PCR setting in 40–80 minutes
A full cycle station from a closed primary tube to a dedicated NC and a finished PCR setting.
Request a quotationPANA9600X automatically opens and closes the tubes, scans samples, loads material, allocates NDT and delivers up to four PCR systems. LIS support, visual consumable recognition, reagent cooling and comprehensive contamination protection provide traceable flow.
Capacity 1-96, dosing range 1-1000 μl, compatibility with 96-well microplates and 6-strips. Heating 35-120 °C, reagent chamber 4-8 °C, Ethernet / USB; dimensions 1370×810×960 mm, weight 235 kg.
Automation of the cycle
- One button starts opening / closing tubes, scanning samples, loading, extraction of NDT and setting PCR
- The full cycle for 96 samples takes 40–80 minutes depending on the reagent.
- Four boot channels and simultaneous installation of four PCR systems
Quality control
- Rotary stirring during extraction, HEPA filter, “smart” droplet capture, strict zoning and UV disinfection reduce the risk of cross-contamination
- Accurate dosing: at volume above 50 μl error ≤1.0%, repeatability CV ≤1.2%
- Barcode reagent scanning and visual recognition of consumables
Compatibility and integration
- Compatible with plasma, serum, whole blood and smear solution
- Cooled chamber of PCR reagents with light protection (4-8 °C)
- Connection to LIS via Ethernet/USB
Throughput
| Parameter | PANA9600X |
|---|---|
| Capacity | 1-96 samples |
| Processing for launch | extraction of 96 samples + setting of 4 PCR systems |
| Full cycle time (96 samples) | 40–80 minutes (depending on the reagent) |
| Types of specimens | plasma, serum, whole blood, smear solution |
| Booting channels | 4 |
| Dosage range | 1-100 μl |
Accuracy of dosing
| Parameter | PANA9600X |
|---|---|
| Accuracy/repeatability (<15 μL) | Δ≤2,0%; CV≤3,0% |
| Accuracy/repeatability (15–50 μL) | Δ≤1,5%; CV≤1,5% |
| Accuracy/repeatability (>50 μL) | Δ≤1,0%; CV≤1,2% |
| Monitoring of fluid levels | CapSense / Gas pressure sensor |
| Accuracy/uniformity of PCR temperature | ±2,0 °C / ±1,2 °C |
Regime and constructiveness
| Parameter | PANA9600X |
|---|---|
| Lysis and elution temperature | 35–120 °C |
| PCR reagent chamber | 4-8 °C, protection from light |
| Extraction costs | 96-well deep microplates, 6-strip tubes |
| Expenditures of PCR | strips 0.1/0.2 ml on 8 tubes, 96-well plates |
| Contamination control | zoning, HEPA filter, UV disinfection, anti-drop design |
| Interfaces | Ethernet, USB |
| Display | 12.1 "touch" |
| Weight | 235 kg |
| Dimensions | 1370×810×960 mm (D×Sh×V) |
| Power supply | AC 100–240 V, 50–60 Hz |