
Xian Tianlong
Automatic nucleic acid extractor of the GeneFlex series
Modular extraction of NA with a flexible capacity of 16×n – from 16 to 192 samples
Compact modular extraction of nucleic acids with a flexible capacity of 16×n.
Request a quotationGeneFlex uses rotary mixing and independent modules, allowing you to run different protocols in parallel without mutual influence. Autorecognition of reagents, UV and ozone disinfection, negative pressure with HEPA and control from a touch screen or mobile device support a safe workflow.
GeneFlex 16/32/48/96/192 line: processing volume of 20-1700 μl, recommended sample volume of 200-500 μl, rotation speed of 100-3000 rpm Lysis and elution are regulated separately in the range of 30-120 °C; intermoon variability CV < 3%, magnetic particle residue ≤ 1%.
Flexibility and productivity
- 16×n: 16 to 192 samples, depending on configuration
- Independent extraction modules allow for simultaneous operation of different protocols without mutual influence.
- Rotational stirring (RMT) reduces aerosol formation
Ease of operation
- 6.86-inch touch screen or control from a smartphone / microplate over Wi-Fi
- Automatic shutdown after UV disinfection, silent operation
- Working with a mobile power source outside the laboratory
- Remote update of the device and reagent protocols
Contamination control
- UV and ozone disinfection, negative pressure, HEPA filtration
- Automatic recognition of reagents and real-time position control of stirrers
- Ability to work inside the biosafety box with highly contagious samples
Throughput
| Parameter | GeneFlex 16 | GeneFlex 32 | GeneFlex 48 | GeneFlex 96 | GeneFlex 192 |
|---|---|---|---|---|---|
| Throughput | 16 | 32 | 48 | 96 | 192 |
| Processing volume | 20–1700 μl | ||||
| Recommended sample size | 200-500 μl | ||||
| Rotation speed | 100-3,000 rpm | ||||
| Intermoon variability | CV≤3% | ||||
| Magnetic particle residue | ≤1% |
Temperature regime
| Parameter | GeneFlex 16 | GeneFlex 32 | GeneFlex 48 | GeneFlex 96 | GeneFlex 192 |
|---|---|---|---|---|---|
| The range of heating of lysis and elution | separately, 30-120 °C | ||||
| Heating speed | 23.8 °C/s |
Design and management
| Parameter | GeneFlex 16 | GeneFlex 32 | GeneFlex 48 | GeneFlex 96 | GeneFlex 192 |
|---|---|---|---|---|---|
| Compatible consumables | Customized 96-well microplates; single 6-strip tubes | ||||
| Controls | 6.86 touch screen; Android app over Wi-Fi | ||||
| Contamination control | Ozone + UV disinfection, negative pressure, HEPA filtering | ||||
| Protection against power outage | Continuation of the experiment with user selection | ||||
| Connection | USB | ||||
| Weight | 7.4 kg | ||||
| Dimensions | 210 × 229 × 242 mm | ||||
| Power supply | AC 100–240 V, 50/60 Hz |
