Analyzer of glycated hemoglobin H8

Lifotronic

Analyzer of glycated hemoglobin H8

Automatic HbA1c determination by HPLC: result in 130 seconds without sample preparation

The H8 is a fully automatic HPLC Lifotronic analyzer for determining HbA1c and examining hemoglobin variants. The device combines the HbA1c result in 130 seconds, automatic analysis preparation and separate modes for hemoglobin and β-thalassemia variants.

Request a quotation

The H8 works on the principle of high-performance liquid chromatography and does not require pre-sample preparation. The loader is designed for 10 samples, and the walk-away mode supports serial automatic processing. The device offers a Variant mode for HbA1c and hemoglobin variants and a β-Thalassemia mode for advanced fraction analysis. Two-wave detection and a built-in degasser support measurement stability, with control performed through a 10.1-inch touchscreen, and built-in memory storing up to 10,000 results.

The method is HPLC. In Variant mode, the analysis time is 130 seconds per test; in β-Thalassemia mode, 380 seconds per test. Loader, 10 samples. In Variant mode, HbF, HbA1c and V-window or S-window are generated; in β-Thalassemia mode, HbF, HbA1c, HbA2 and HbE/D/S/C fractions. Detection is two-wave, degasser is provided. Touch, 10.1 inches; memory, up to 10,000 records; manufacturer indicates traceability of HbA1c results across NGSP and IFCC.

Speed and convenience

  • HbA1c results ready in 130 seconds without manual sample preparation
  • The loader is designed for 10 samples, walk-away mode is supported
  • Control via 10.1 inch touch screen

Analysis modes

  • Variant mode: HbF, HbA1c, V-window or S-window
  • β-Thalassemia mode – HbF, HbA1c, HbA2 and HbE/D/S/C fraction, the test takes 380 seconds

Reliability

  • Two-wave detection reduces the impact of the background signal
  • Built-in degassing system maintains stable pressure in the system
  • Memory can store up to 10,000 results
  • HbA1c results standardized for NGSP and IFCC

Method and productivity

ParameterH8
MethodHPLC (HPLC)
Analysis time, Variant mode130 c/test
Analysis time, β-Thalassemia mode380 s/test
Loading samples10 samples

Indicators to be determined

ParameterH8
Variant modeHbF, HbA1c, V-window (or S-window)
β-Thalassemia modeHbF, HbA1c, HbA2, fractions of HbE/D/S/C

Interface and memory

ParameterH8
Displaysensory, 10.1 inches
Memory.up to 10,000 results
StandardizationNGSP, IFCC