Micro Solutions Life ScienceRU

Micro Solutions / Life Science

Consumables for electrophoresis Cleaver Scientific

Agarose, DNA and protein markers, combs and tips for gel electrophoresis and blotting

Product overview

Agarose, DNA and protein markers, combs and tips for gel electrophoresis and blotting

a set of consumables of the CleverGEL line for the daily work of the laboratory

Cleaver Scientific offers a set of consumables for gel electrophoresis and blotting: several types of CleverGEL agarose, ready-made DNA and protein markers, color-coded combs, sample tips and self-adhesive IdentiTapes labeling tapes.

The line of supplies covers the basic daily needs of the molecular laboratory. CleverGEL agarose comes in several modifications - from universal Low EEO to high-resolution PCR-grade, light melt for nucleic acid isolation and tablet for quick preparation of the gel. Ready-to-use DNA markers. The four-band and Pink Plus and Blue Wide Range protein markers contain an indicator dye and do not require additional preparation before application. The combs come in four color-coded thicknesses for preparative and high-resolution tasks, and the tips for applying samples in three versions facilitate the loading of thin PAGEs and the combing of the comb. IdentiTapes self-adhesive tapes are used to mark test tubes and samples, including storage at negative temperatures.

CleverGEL Low EEO agarose: melting point 88±1.5 °C, gelation point 36±1.5 °C, gel strength >1200 g/cm² (1% gel). High Resolution: melting ≤70 °C, strength ≥750 g/cm² (1.5% gel), fragment resolution 20–800 bp. Low Melting Point: melting ≤65 °C, gelation 26–30 °C, for fragments from 200 bp to 25 kb. DNA markers CSL-MDNA-50BP/100BP/100BPH/1KBPLUS cover 50–1500, 100–1500, 100–3000 bp and 100 bp–10 kb; load 5 µL/well, storage 6 months at 25 °C or 12 months at 4 °C. Protein markers CSL-PPL (10–175 kDa) and CSL-BBL (10–245 kDa) are loaded at 2.5–5 µL/well. Combs have thicknesses 0.75/1.0/1.5/2.0 mm, color coded black/white/red/blue. Sample-loading tips use a 33 mm microcapillary for 5 µL and tip diameters 0.57, 0.37 and 0.17 mm. IdentiTapes withstand −20…+121 °C and can be marked with a ballpoint pen, pencil or marker.

Key figures

4

clevergel

4

DNA-marker range

10-245 kDa

protein-marker range

0.75-2 mm

comb-thickness

Applications

Models and configurations

CleverGEL agarosa

DNA and protein markers

Crests and tips

CleverGEL agarosa

Model rangeLow EEO, High Resolution (PCR grade), Low Melting Point, Instant Agarose Tablets
Melting point88±1,5 °C (Low EEO/Instant); ≤65 °C (LMP); ≤70 °C (High Resolution)
Geliac temperature36±1,5 °C (Low EEO/Instant); 26–30 °C (LMP); ≤33 °C (High Resolution)
Gel strength>1200 g/cm2 (Low EEO/Instant, 1%); >200 g/cm2 (LMP, 1%); >750 g/cm2 (High Resolution, 1.5%)
Packing5g and 100g (Low EEO); 5g and 50g (LMP)

DNA markers

Ranges50–1500 p.N.; 100–1500 p.N.; 100–3000 p.N.; 100 p.N.—10 t.B.
Number of lanes17; 11; 12; 13, respectively;
Storage6 months at 25 °C; 12 months at 4 °C; 24 months at −20 °C
Volume of application5 μl/well
Tracking dyeOrange G, Xylene Cyanol FF, bromphenol blue

Protein markers

Pink Plus10–175 kDa, 11 bands, 10, 40 and 90 kDa reference bands
Blue Wide Range10–245 kDa, 12 lanes, 25 and 75 kDa reference strips
Volume of application2.5–5 μl/well
Storage3 months at 4 °C; 24 months at -20 °C

Crests.

Thickness (color)0.75 mm - black; 1.0 mm - white (standard); 1.5 mm - red; 2.0 mm - blue
PurposeBlack/white for clear high resolution bands; red/blue for increased sample volume

Sampling tips

Enforcementround 0.57 mm (gels 0.75–1.5 mm); flat 0.37 mm (sequencing gels 0.4 mm); ultra-thin flat 0.17 mm (wedge gels 0.2 mm)
Microcapillarylength 33 mm, volume 5 μl
Compatibilitysingle-channel pipette

IdentiTapes

Materialpaper-ribbon, water-, oil- and acid-resistant
Temperature range-20 °C to +121 °C
Inscriptionballpoint pen, pencil, marker