CEM
Vessels and consumables for microwave decomposition CEM MARS 6
CEM interchangeable vessels for different types of samples - from routine to complex matrices
CEM interchangeable vessels for the MARS 6 microwave decomposition system range from routine EPA methods to complex organic and inorganic matrices.
Request a quotationThe line includes iPrep, MARSXpress, MARSXpress Plus and EasyPrep Plus vessels, which are installed in the MARS 6 rotor and automatically recognized by the system by type and quantity. Each type of vessel has its own way of controlling temperature - from the combination of an IR sensor and iWave to fiber-optic measurement, which allows you to select the vessel for the purpose of the test. Additional accessories — the AutoCal 2.0 calibrator, the MARSXpress Capping Station and the antistatic ionizer — simplify maintenance and increase reproducibility.
MARSXpress is a three-component vessel with a volume of 20, 55 or 75 ml with automatic discharge and re-sealing of pressure, IR / iWave control, up to 40 vessels per cycle; suitable for routine samples using EPA methods. MARSXpress Plus - the same principle, increased volume of 110 ml, up to 24 vessels per cycle, for geological, catalyst and battery materials. EasyPrep Plus is a pressure vessel with a volume of 100 ml, up to 12 vessels per cycle, with fiber-optic and iWave temperature control, for complex inorganic matrices with HCl / HF. iPrep is a double-seal vessel with a volume of 110 ml, up to 16 vessels per cycle, with iWave control, for the most complex organic samples (PET, petroleum products).
Receptacle selection
- MARSXpress - three-component vessel with automatic discharge and re-sealing of pressure, up to 40 vessels per cycle
- MARSXpress Plus – increased volume for larger samples of the same application group
- EasyPrep Plus - a vessel of high pressure and temperature with a minimum of assembly parts, without springs and membranes
- iPrep – double sealed vessel, the greatest temperature and pressure range
Monitoring and maintenance
- The type of temperature control depends on the vessel: IR/iWave, fiber-optic/iWave or only iWave.
- AutoCal 2.0 – NIST-tracked calibration of iWave and IR sensors
- MARSXpress Capping Station automates closure and unblocking of vessels of the MARSXpress series
Vascular parameters
| Parameter | MARSXpress | MARSXpress Plus | EasyPrep Plus | iPrep |
|---|---|---|---|---|
| Temperature monitoring | IC/iWave | IC/iWave | fibre-optic/iWave | iWave |
| Maximum receptacles per cycle | 40 | 24 | 12 | 16 |
| Volume, ml | 20, 55, 75 | 110 | 100 | 110 |
Typical samples
| Parameter | MARSXpress | MARSXpress Plus | EasyPrep Plus | iPrep |
|---|---|---|---|---|
| Matrixes | EPA-methods: ecology, food products, feed, fertilizers, pharmaceuticals, tissues, polymers | geological materials, ceramics, catalysts, precious metals, coal, slags, battery materials | the same as MARSXpress Plus, as well as petroleum products and flame retardants | complex organic samples: petroleum products, PET, large hangings |