HFsafe LC Biosafe Box (900LC/1200LC/1500LC/1800LC)

Heal Force

HFsafe LC Biosafe Box (900LC/1200LC/1500LC/1800LC)

Class II type A2 with Flow-saFe system: automatic flow balance for four standard sizes

Heal Force HFsafe LC is a series of Type II A2 biosafety boxes with the patented Flow-saFe system for automatic balance of incoming and downstream. Four sizes - 900LC, 1200LC, 1500LC and 1800LC - are combined in one card, as they are built on a common technological platform.

Request a quotation

Boxing generates controlled incoming and downstream airflows, filters incoming and outgoing air, and maintains a safe work area for biological material operations. Flow-saFe automatically balances flow rates; two independent temperature-compensated sensors monitor downstream and exhaust flow. The LCD interface displays air condition, glass position, working area temperature, filter life and operating time, and when the front door is closed, the fan speed automatically decreases. The work chamber is made of 304 stainless steel with seamless surfaces; programmable UV processing and locking simplify cleaning and locking. safe operation.

Class II, type A2. For the sizes 900LC/1200LC/1500LC, the outer dimensions are 1040×790×2130, 1340×790×2130 and 1640×790×2130 mm, the inner dimensions of the working area are 950×575×625, 1250×575×625 and 1550×575×625 mm respectively; the incoming flow speed is 0.53±0.025 m/s and the downstream flow is 0.35±0.025 m/s the same for all sizes, the noise level is the same for all sizes. grows with a width of no more than 60, 63 and 65 dB, illumination of the working area is not less than 1000 lux, maximum power consumption 1600 W (900LC, 1200LC) and 2000 W (1500LC). Data for 1800LC on verified sources are not found. Intake and exhaust ULPA filters have a declared typical efficiency of 99.999% for particles 0.1-0.2 μm; The capacity is tested by KI-Discus method according to EN 12469. NSF 49 and EN 12469N certificates are confirmed for the series; power supply is 220 V, 50 Hz.

Control of airflows

  • The patented Flow-saFe system automatically supports the ratio of incoming and downstream streams
  • Two independent temperature-compensated sensors monitor downstream and exhaust flows
  • When closing the front sash, the system automatically reduces the fan speed

Indication and monitoring

  • LCD-interface shows air parameters, temperature of the working area, filter resource, operating time and alarm messages
  • Test of restraint by KI-Discus confirmed according to EN 12469

Construction and maintenance

  • 304 stainless steel working chamber with seamless surfaces and removable sections
  • Programmable UV Decontamination with Protective Blocking

Protection class

Parameter900LC1200LC1500LC1800LC
Type of boxingClass II, type A2

Dimensions and mass

Parameter900LC1200LC1500LC1800LC
External dimensions (W×D×H)1040×790×2130 mm1340×790×2130 mm1640×790×2130 mm—
Internal dimensions of the working area (WxGxB)950×575×625 mm1250×575×625 mm1550×575×625 mm—

Airflow

Parameter900LC1200LC1500LC1800LC
Incoming flow rate0.53 ± 0.025 m/s
Downstream velocity0.35 ± 0.025 m/s
Noise level≤60 dB≤63 dB≤65 dB—
Illumination of the work area≥ 1000 lux

Filtration

Parameter900LC1200LC1500LC1800LC
FilterULPA
Filter efficiency99.999% for particles 0.1–0.2 μm

Power supply and certificates

Parameter900LC1200LC1500LC1800LC
Power supply220 V, 50 Hz
Maximum power consumption1600 watts1600 watts2000 W.—
CertificatesNSF 49, EN 12469N, CFDA