Micro Solutions

Analytical solutions for your laboratory

RU
Laser for Hamilton Thorne Lykos Auxiliary Hatching

Gynemed, Hamilton Thorne

Laser for Hamilton Thorne Lykos Auxiliary Hatching

Clinical laser for hatching and embryo biopsy with optional dynamic beam guidance DTS

LYKOS is a clinical laser for assisted hatching and embryo biopsy, available in fixed design and in DTS execution with computer-guided beams along a given trajectory.

Request a quotation

Hamilton Thorne's LYKOS laser comes in the Gynemed range and is used for assisted hatching, pellucide thinning and embryonic biopsy (blastomer and trophectoderm). The 40x lens-based laser module is compatible with most inverted microscopes. The RED-i target designator is visible through the eyepieces and on the screen. Isothermal rings display the expected hole size and maximum temperature. The LYKOS DTS execution additionally provides a dynamic targeting system with a choice of laser trajectory, automatic calibration upon initialization, and the formation of quality control reports with trend graphs — these are the types of systems that are designed to be used to control the impact of the laser. There are no fixed functions in LYKOS.

LYKOS uses a solid-state infrared diode laser with a wavelength of 1460 nm and a power of 300 mW, safety class 1. In clinical mode, three fixed pulse durations are available - 200, 400 and 600 μs; in Multipulse mode - a series of pulses lasting 1-3000 μs at an average power of 10 mW. Dimensions of the laser module: LYKOS (fixed) – 42×32×32 mm, LYKOS DTS – 42×34×34 mm Power – 100–240 V AC; HT Laser 6 software runs Windows 7, 8, 10 or 11 and supports several languages, including Russian.

Laser and safety

  • Solid-state IR diode laser 1460 nm with a capacity of 300 mW, safety class 1
  • Clinical mode with fixed pulse settings of 200, 400 and 600 μs
  • Multipulse mode – a series of pulses of 1–3000 μs at an average power of 10 mW

Dynamic guidance DTS

  • Selection of trajectory: point, line/curve, arbitrary shape, up to 25 points, rectangle, arc
  • Change in size and position of trajectory before exposure
  • Automatic calibration and initialization of the system

Quality control and SOE

  • RED-i target designator, visible in eyepieces and on screen
  • Isothermal rings are six concentric circles that represent the size of the hole and the temperature.
  • HT Laser 6 software with quality control reports and trend charts, multilingual interface (including Russian)

laser

ParameterLYKOSLYKOS DTS
Type of lasersolid-state IR diode, 1460 nm
Power300 mW
Security class1 (Class 1)
Duration of pulse, clinical regimen200, 400 or 600 μs
Pulse duration, Multipulse mode1–3000 μs with an average power of 10 mW
Objective40× compatible with most inverted microscopes

Differences in performance

ParameterLYKOSLYKOS DTS
Beam guidancetarget-signatureDTS system: computer guidance on a given trajectory
Calibration—automatic calibration during initialization
Quality control reports—trend-line
Dimensions (W×SH×G)42×32×32 mm42×34×34 mm

Power and software

ParameterLYKOSLYKOS DTS
Power supply100–240 V AC
Operating systemWindows 7, 8, 10, 11