Gram Bioline
Explosive Refrigerator ExGuard ER600W
Safe storage of substances with toxic or explosive discharges and auto-exhaust before access
Gram BioLine ExGuard ER600W is a specialized laboratory refrigerator for safe temperature storage of materials capable of releasing toxic, unpleasant smelling or explosive fumes.
Request a quotationThe cabinet connects to the existing exhaust ventilation. A separate controller controls the damper and blocks the door opening until the potentially hazardous atmosphere inside the chamber is removed and replaced by room air. The order and duration of the access stages are customized to a specific process. The additional BioPlus controller controls the process. temperature, acoustic and visual alarms; solid or glass door, shelves and retractable modules are available.
ExGuard ER600W operates in the range of -2 ... +20 °C. Dimensions - 820 × 789 × 1996/2246 mm, total volume 614 liters, useful volume 486 liters, weight without packaging and options - 166 kg Internal chamber is made of stainless steel; provided up to 47 shelves or 9 boxes, port with a diameter of 24.5 mm, refrigerant R290, power 230 V, 50 Hz, 16 A. It is 1.62 kWh/day with a solid door and 2.08 kWh/day with glass; noise level is 46.3 dB(A). Internal and external design corresponds to ATEX Category 3 Zone 2, marking II 3G Ex ec ic IIB T2 Gc.
Security of access
- A dedicated extraction controller blocks the door from opening until the potentially dangerous atmosphere inside the chamber is replaced by room air.
- The controller-controlled valve connects to the building’s existing exhaust system to remove potentially contaminated air.
- The order and duration of access stages are configured for a specific process.
- Simple access procedure requires minimal staff training
Temperature control
- BioPlus Controller Controls Temperature, Acoustic and Visual Anxieties
- 24.5 mm port for external sensors, additional E-sensor and container simulator for temperature reference
- Gram BioLine’s Forced Air Distribution Keeps Temperature Stable
Design
- Stainless internal chamber, shelves and box brackets, guides
- Internal and external markings of ATEX Category 3 Zone 2
- Solid or glass door to choose from when ordering
Temperature and regimen
| Parameter | ER600W |
|---|---|
| Temperature range | −2…+20 °C |
| Permissible room temperature | solid door +10 ... +43 °C; glass door +10 ... +38 °C |
| Extraction controller | Dedicated ExGuard controller and software that blocks access to the camera until safe atmospheric extraction; separate BioPlus controller for normal operation |
Dimensions and volume
| Parameter | ER600W |
|---|---|
| Dimensions (W×D×H) | 820 x 789 x 1996/2246 mm |
| Total volume | 614 l |
| Useful volume | 486 l |
| Mass without options | 166 kg |
| Modules for shelves and drawers | up to 48 shelves or 9 boxes |
Refrigerant and energy consumption
| Parameter | ER600W |
|---|---|
| Refrigerant | R290 |
| Refrigeration capacity at -10 °C | 389 W |
| Energy consumption | 1.62 kWh/day with solid door; 2.08 kWh/day with glass door |
| Noise level | 46.3 dB(A) |
| Heat transfer coefficient (K) | solid door 0.26 W/(m2·K); glass door 0.45 W/(m2·K) |
Design
| Parameter | ER600W |
|---|---|
| Materials of the inner chamber | stainless-steel |
| Case material | white-coloured steel or stainless steel |
| Isolation. | 70 mm polyurethane foam, without HFC propellant cyclopentane |
| Ground | Feet; wheels available without extra charge |
| Power supply | 230 V, 50 Hz, 16 A |
| Port port | 1 × 24.5 mm |
| ATEX marking | II 3G Ex ec ic IIB T2 Gc |