Erba
H 560 hematology analyzer
5-part differential CBC with laser flow cytometry from a 15 µL sample
A five-part differential hematology analyzer for laboratories that need an extended white-cell differential without making daily operation more complex.
Request a quotationIt performs CBC and 5-part differential analysis using whole, prediluted, or capillary blood. Electrical impedance measures RBC, PLT, and WBC; three-angle laser flow cytometry differentiates white cells; cyanide-free colorimetry measures hemoglobin. LIS connectivity, quality control, and results with plots are supported.
Up to 60 tests per hour and 32 parameters. Whole-blood volume: 15 µL; CBC mode: 11 µL. Stores 50,000 results with plots. Dimensions: 364 × 498 × 431 mm; weight: 26.5 kg. 4 USB ports and LAN.
5-diff accuracy
- Three-angle laser flow cytometry for full 5-diff with just three reagents
- 15 μl of whole blood (11 μl in CBC mode only)
- Electrical impedance for RBC/PLT/WBC, cyanide-free colorimetry for Hb
- Detailed information about platelets: P-LCR, P-LCC, PDW-SD, PDW-CV
Structural reliability
- Compact housing 364×498×431 mm, weight 26.5 kg
- Technology to protect the aperture from suction by a high voltage pulse after each test
- Accepting test tubes from different manufacturers, including pediatric
- Device status indicator
Ease of operation
- 10.4 touch screen, one-click analysis, full RFID traceability
- Automatic diluent delivery (ADDM) reduces preanalytic errors
- 6 analytical modes: manual, pre-examination, capillary, etc.
- Memory for 50,000 results with graphs, 4 USB + 1 LAN
Measurement
| Parameter | H 560 |
|---|---|
| Parameters | 32, including WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV/SD, PLT, MPV, PDW-CV/SD, PCT, P-LCR, P-LCC, 5-diff leukoformula (Neu, Lym, Mon, Eos, Bas, %/#); ALY, LIC, NRBC – only for scientific research |
| Principle of measurement | RBC/PLT/WBC – electrical impedance; DIFF – triangular laser flow cytometry; HGB – cyanide-free colorimetry |
| Histograms and scatterograms | 3 histograms (WBC/RBC/PLT); 4 scatterograms (DIFF×3, BASO) |
| Throughput | up to 60 tests per hour |
Sample and reagents
| Parameter | H 560 |
|---|---|
| Sample size | 15 μl (whole blood); 11 μl (CBC only); 20 μl (pre-diluted/capillary) |
| Calibrator | ELite H Cal, 3 ml, stability after opening 7 days at 2-8 °C |
| Control materials | Erba H5 CON L/N/H, 3 ml, stability after opening 14 days at 2–8 °C |
Data and constructiveness
| Parameter | H 560 |
|---|---|
| Memory of results | 50,000 with charts |
| Interfaces | 4 USB + 1 LAN |
| Dimensions | 364×498×431 mm |
| Massa | 26.5 kg |
| Power supply | AC 100–240 V, 50/60 Hz, ≤200 VA |
| Conditions of operation | 15–30 °C, 70–106 kPa |
| Conformity | CE (IVDR requirements) |