Micro Solutions

Analytical solutions for your laboratory

RU
H 560 hematology analyzer

Erba

H 560 hematology analyzer

5-part differential CBC with laser flow cytometry from a 15 µL sample

A five-part differential hematology analyzer for laboratories that need an extended white-cell differential without making daily operation more complex.

Request a quotation

It performs CBC and 5-part differential analysis using whole, prediluted, or capillary blood. Electrical impedance measures RBC, PLT, and WBC; three-angle laser flow cytometry differentiates white cells; cyanide-free colorimetry measures hemoglobin. LIS connectivity, quality control, and results with plots are supported.

Up to 60 tests per hour and 32 parameters. Whole-blood volume: 15 µL; CBC mode: 11 µL. Stores 50,000 results with plots. Dimensions: 364 × 498 × 431 mm; weight: 26.5 kg. 4 USB ports and LAN.

5-diff accuracy

  • Three-angle laser flow cytometry for full 5-diff with just three reagents
  • 15 μl of whole blood (11 μl in CBC mode only)
  • Electrical impedance for RBC/PLT/WBC, cyanide-free colorimetry for Hb
  • Detailed information about platelets: P-LCR, P-LCC, PDW-SD, PDW-CV

Structural reliability

  • Compact housing 364×498×431 mm, weight 26.5 kg
  • Technology to protect the aperture from suction by a high voltage pulse after each test
  • Accepting test tubes from different manufacturers, including pediatric
  • Device status indicator

Ease of operation

  • 10.4 touch screen, one-click analysis, full RFID traceability
  • Automatic diluent delivery (ADDM) reduces preanalytic errors
  • 6 analytical modes: manual, pre-examination, capillary, etc.
  • Memory for 50,000 results with graphs, 4 USB + 1 LAN

Measurement

ParameterH 560
Parameters32, including WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV/SD, PLT, MPV, PDW-CV/SD, PCT, P-LCR, P-LCC, 5-diff leukoformula (Neu, Lym, Mon, Eos, Bas, %/#); ALY, LIC, NRBC – only for scientific research
Principle of measurementRBC/PLT/WBC – electrical impedance; DIFF – triangular laser flow cytometry; HGB – cyanide-free colorimetry
Histograms and scatterograms3 histograms (WBC/RBC/PLT); 4 scatterograms (DIFF×3, BASO)
Throughputup to 60 tests per hour

Sample and reagents

ParameterH 560
Sample size15 μl (whole blood); 11 μl (CBC only); 20 μl (pre-diluted/capillary)
CalibratorELite H Cal, 3 ml, stability after opening 7 days at 2-8 °C
Control materialsErba H5 CON L/N/H, 3 ml, stability after opening 14 days at 2–8 °C

Data and constructiveness

ParameterH 560
Memory of results50,000 with charts
Interfaces4 USB + 1 LAN
Dimensions364×498×431 mm
Massa26.5 kg
Power supplyAC 100–240 V, 50/60 Hz, ≤200 VA
Conditions of operation15–30 °C, 70–106 kPa
ConformityCE (IVDR requirements)