Erba
Coagulometer ECL 760
Fully automatic random-access coagulometer: up to 60 PV tests per hour
Fully automatic coagulometer for combining routine and special studies of hemostasis on one compact platform.
Request a quotationRandom-access performs clotting, chromogenic and immunoturbidimetric tests, supports urgent samples and user techniques. Automatically monitors samples and reagent levels, reads barcodes, performs breeding, calibration and quality control.
Up to 60 PV tests per hour or 40 mixed-mode tests: seven independent measuring channels: 640 nm for clotting, 405 nm for chromogenic and 575 nm for immunoturbidimetric tests. On board 27 samples, up to 23 vials of 13-15 °C cooling reagents and 72 cuvettes. Dimensions 650 × 580 × 510 mm, weight 53 kg.
Throughput
- Random-access with full walk-away mode
- Up to 60 PV tests per hour or 40 mixed PV/APTV tests
- Automatic pre-contamination and sampling
- Priority of STAT tests
Reliability and quality
- Password protection of the operator
- Automatic control of reagent levels on board
- Barcoding of samples for positive identification
- Levey-Jennings automatic QC program, up to 12 levels of control
Flexibility
- Customized special menu with reflex testing and customizable profiles
- Open Programming of User Methods
- Combining routine and special reagents on one platform
Measurement
| Parameter | ECL 760 |
|---|
| Principle | photooptic |
|---|
| Channels | 7 independent channels: clotting 640 nm, chromogenic 405 nm, immunoturbidimetry 575 nm |
|---|
Throughput
| Parameter | ECL 760 |
|---|
| PV | 60 tests per hour |
|---|
| PV/APTV (mixed mode) | 40 tests per hour |
|---|
Samples and reagents
| Parameter | ECL 760 |
|---|
| Sampling area | 27 samples on board, continuous loading and unloading of tripods |
|---|
| Reagent zone | up to 23 vials, cooling 13-15 °C, automatic level detection |
|---|
| Expenditure | 72 cuvettes (2 cassettes), RFID control |
|---|
Calibration and QC
| Parameter | ECL 760 |
|---|
| Calibration | up to 6 levels for analysis, automatic, active curve storage |
|---|
| Quality control | Up to 12 control levels, Levey-Jennings automatic graphics, Multi Rules |
|---|
PO and liaison
| Parameter | ECL 760 |
|---|
| Software | Windows, ASTM protocol |
|---|
| Connection | bidirectional RS-232, built-in thermal printer |
|---|
| Memory. | over 10,000 result curves |
|---|
Dimensions and power supply
| Parameter | ECL 760 |
|---|
| Sizes. | 650 x 580 x 510 mm |
|---|
| Weight | 53 kg |
|---|
| Power supply | 100–240 V (±10%), 50/60 Hz, 400 VA |
|---|