ELITech
Vapro vapor phase osmometer 5600
Osmolyte microsamples from 2 μl by vapor pressure in ~90 seconds
Vapro 5600 is an ELITech vapor-phase osmometer to determine the osmolality of microsamples with a volume of 2 μl. The method of reducing vapor pressure allows you to examine viscous samples and suspensions without interference associated with freezing; a typical measurement takes about 90 seconds.
Request a quotationThe device determines the osmolality of the dew point temperature reduction over a sample in equilibrium at room temperature, is designed for serum, urine and other biological or process fluids and is suitable for clinical, research and pharmaceutical applications. The standard holder takes 10 µL; holders for 2, 20 and 60 µL are also available. Automatic calibration, thermocouple self-cleaning, self-diagnostics, statistical functions and transfer of results to the computer support a standardized workflow.
Model 5600: Vapour pressure osmometry, recording dew point temperature drops. Nominal sample volume is 10 μl; optionally 2, 20 or 60 μl. Range is 20–3200 mOsm/kg, with XR expansion to 3,500 mmol/kg. Typical analysis time is about 90 s; resolution is 1 mmol/kg; repeatability is 2 mmol/kg SD. Display is monochrome LCD 240×128 with backlit dimensions 20×28×36 cm; weight 6.8 kg Power 100–240 V, 50–60 Hz; maximum power consumption 40 W.
Accuracy of measurement
- The method of reducing vapor pressure determines osmolality at room temperature, which excludes artifacts characteristic of cryoscopic methods at high viscosity or suspended particles.
- The error is not more than ±1% in the calibrated range of 100-1000 mOsmol / kg
- Self-cleaning thermocouple and self-diagnosis reduce maintenance needs
Ease of operation
- Automatic calibration and menu-oriented interface in 4 languages
- Sample holders for 2, 10, 20 and 60 μl for different sample volumes
- VQC program for online comparison of quality control results with other laboratories around the world
Measurement
| Parameter | Vapro 5600 |
|---|---|
| Method | vapor pressure osmometry (decrease in dew point temperature) |
| Nominal sample size | 10 μl (additional 2, 20 or 60 μl) |
| Range. | 20–3,200 mOsmol/kg, up to 3,500 mmol/kg with XR expansion |
| Time for analysis | ~90s |
| Permission | 1 mmol/kg |
| Repeatability | 2 mmol/kg SD |
| Linearity | ±1% (100–1000 mOsmol/kg), ±5% outside the range of up to 3,200, ±10% >3,200 for XR |
Construction and power supply
| Parameter | Vapro 5600 |
|---|---|
| Display | monochrome LCD 240×128 points, backlit |
| Dimensions (WxVxG) | 20×28×36 cm |
| Weight | 6.8 kg |
| Power supply | 100–240 V, 50–60 Hz, up to 40 W |