ELITech
Aerospray Hematology Stat
Fast water coloring of blood smears: cycle of 2-4 minutes, up to 450 slides per hour
The Aerospray Hematology Stat is an automatic liner and optional cytocentrifuge for rapid, standardized smearing of blood, bone marrow, and other bodily fluids. Water dyes, a 2-4 minute cycle, and microscopy-ready dry glass support urgent and routine hematology.
Request a quotationThe system sprays fresh thiasine and eosin dyes directly onto the glass in a rotating carousel, reducing the risk of cross-contamination. Fast mode, Wright-Giemsa, May-Grünwald-Giemsa and custom settings, seven intensity levels for peripheral blood and three for bone marrow. Flushing and drying form microscopy-ready glass. The optional Cytopro rotor turns the device into an eight-position cytocentrifuge for urine, CSF, pleural fluids and other biological fluids. The system supports barcoding, traceability of samples and reagents, user logs and level control.
Model 7122. Carousel capacity - 1-12 slides; declared performance - approximately 450 slides / h. Rapid color cycle takes 2-4 minutes. The speed of the optional Cytopro rotor - 100–2000 rpm with an accuracy of ±5%; capacity - 8 cameras and 8 slides. Display - touch 7-inch LCD WVGA. Dimensions - 57×25×54 cm, height with an open cover - 58 cm; weight - 16.3 kg. Power - 100-240 V, 50-60 Hz, up to 200 W.
Speed and reliability
- The full cycle takes 2-4 minutes, the slide dries and is ready for microscopy immediately after painting.
- A fresh portion of thiazine and eosin dyes is applied to each glass, which reduces the risk of material transfer.
- The buffer solution washes the slide from excess dye, after which centrifugation accelerates drying.
Colour flexibility
- Seven levels of intensity for peripheral blood and three for bone marrow
- Basofix scheme available for more pronounced basophil granules coloring
- With the Cytopro rotor, the device becomes an eight-position cytocentrifuge
Traceability
- Touch 7-inch WVGA display
- Barcoding and logs of samples, reagents and users
- Automatic waste control (option)
Throughput
| Parameter | Aerospray Hematology Stat |
|---|---|
| Carousel capacity | 1-12 slides |
| Colouring cycle | 2-4 minutes |
| Throughput | ~450 slides/h (calculated) |
| Cytopro rotor speed (optional) | 100–2,000 rpm ±5%, programmable |
Construction and power supply
| Parameter | Aerospray Hematology Stat |
|---|---|
| Display | Sensor 7" LCD WVGA |
| Dimensions (WxVxG) | 57×25×54 cm |
| Height with open lid | 58 cm |
| Weight | 16.3 kg |
| Power supply | 100–240 V, 50–60 Hz, up to 200 W |
Security and control
| Parameter | Aerospray Hematology Stat |
|---|---|
| Locking the lid | the cover is locked during the rotation of the carousel |
| Control of reagent level | sensors on all feed lines |
| Control of waste management | Sensor in a waste bottle (option) |