288
slide/h max. (with 30-pose carousel)
Micro Solutions / Life Science
Automatic smears of blood and bone marrow – up to 288 slides per hour

Automatic smears of blood and bone marrow – up to 288 slides per hour
Wright-Giemsa alcohol programs and optional Cytopro cytocentrifuge
Aerospray Hematology Pro is an automatic blood and bone marrow smear stener with the ability to operate in cytocentrifuge mode. Alcohol staining programs, loading up to 30 slides and flexible intensity tuning help standardize morphological studies at high laboratory loads.
The device sprays fresh reagents with aerosol spray on glass rotating in a carousel, so the samples do not come into contact with the previously used dye. Supports programs Rapid Wright-Giemsa, Wright-Giemsa, May-Grünwald-Giemsa and custom coloring; for each there are nine intensity levels. With an optional Cytopro rotor, the device performs cytocentrifugation of biological fluids on eight glasses. The sensor interface, reagent, sample and user records, USB history export and level control simplify standardization and traceability.
Model 7152: Carousel capacity - 1-12 or 1-30 slides depending on the installed carousel. cycle duration - from 5 minutes; performance - more than 115 slides / h, up to 288 slides / h with an optional 30-position carousel. Cytopro rotor speed - 100–2000 rpm, programmable; rotor designed for 8 cameras and 8 slides. - 57×25×54 cm, height with an open lid - 58 cm; weight - 15.2 kg. Power - 100-240 V, 50-60 Hz, up to 200 W.
slide/h max. (with 30-pose carousel)
coloring-level
minimum cycle time
brochure
spraying of fresh reagent on each glass
individual nozzles for each reagent
| Carousel capacity | 1–12 or 1–30 slides (depending on the carousel) |
|---|---|
| Cycle duration | 5 minutes |
| Throughput | more than 115 slides / h, up to 288 slides / h with a 30-position carousel |
| Cytopro rotor speed (optional) | 100–2,000 rpm, programmable |
| Dimensions (WxVxG) | 57×25×54 cm |
|---|---|
| Height with open lid | 58 cm |
| Weight | 15.2 kg |
| Power supply | 100–240 V, 50–60 Hz, up to 200 W |
| Locking the lid | the cover is locked during the rotation of the carousel |
|---|---|
| Control of reagent level | sensors on all feed lines |
| Control of waste management | waste-bottle |
Turns a Steiner into an eight-position programmable cytocentrifuge
Basic chamber for cytocentrifugation with good cell repair
Application of two samples to one glass to save consumables
For samples up to 6 ml in volume
Buffer pH 6.8 / pH 7.2 to complete the coloring cycle
Coloration of basophilic cell structures
Staining of acidophilic cell structures
Fixing smears before painting