40
sample/cycle
Micro Solutions / Life Science
Random access ELISA and clinical chemistry analyzer on one platform: up to 40 tests per cycle

Random access ELISA and clinical chemistry analyzer on one platform: up to 40 tests per cycle
with disposable barcoded reagent cartridges and pre-sampling up to 1:1000
DRG:HYBRiD-XL is a compact fully automatic analyzer that combines enzyme immunoenzyme and clinical-chemical studies on a single desktop platform.
The system performs random-access studies from one download and allows you to form individual panels from immunoenzyme, clinical-chemical and immunoturbidimetric tests. Ready-made barcoded cartridges, automatic assignment of tests, sample preview, fluid level control and clot reduce the number of manual operations; Bidirectional communication supports integration with the laboratory information system.
Up to 40 samples or 40 tests at a time, one cartridge test. Three holders of 12 primary tubes 13/16 mm or two holders of 20 secondary tubes 8 mm; minimum sample volume 5 μl for tubes 8 mm, pre-examination up to 1: 1000. 12 wavelengths are available; walk-away modes depend on the test: 10, 60, 90, 120 or 150 minutes plus 15 minutes Warming. 23.6 x 23.6 x 24.8 inches, 125.7 pounds.
sample/cycle
wavelengths
min sample
preconception
random access analyzer
cartridge-system
| Format of analysis | random access, one test on the cartridge |
|---|---|
| Simultaneous samples/tests | 40 |
| Time to finish | 10/60/90/120/150 min depending on the test + 15 min warming up |
| Tube holders | 3 holders of 12 primary tubes 13/16 mm or 2 holders of 20 secondary tubes 8 mm |
|---|---|
| Minimum sample size | 5 μl (tube 8 mm) |
| Prejudice | up to 1:1000, automatic, in individual cartridges |
| Types of specimens | serum, plasma, urine, saliva |
| Photometry | 12 wavelengths |
|---|---|
| Identification | barcoding of samples and reagent cartridges |
| Dimensions (W×D×H) | ≈599×599×630 mm |
| Weight | ≈57 kg |
| Interface. | bidirectional, for LIS |
|---|---|
| Reagent stability period | 12 months from the date of production |
| System reagents | flushing-mortar |
17-OH progesterone, estradiol, LH, FSH, prolactin, testosterone, free testosterone, AMH, beta hCG
AFP, beta-hCG, PSA, free PSA, CA 72-4
T3, T4, free T3 and T4, TSH
HbA1c, insulin, C-peptide
D-dimer, CRP highly sensitive
calprotectin, pancreatic elastase, antibodies to tTG and DGP (IgA/IgG)
ceftazidim, ciprofloxacin, linezolid, piperacillin, procalcitonin
aldosterone, active renin