Micro Solutions

Analytical solutions for your laboratory

RU
Cellular Analyzer Guava Muse

Cytek

Cellular Analyzer Guava Muse

Compact desktop cell analyzer with ready mix-and-read sets and touch screen

A compact cellular analyzer for rapid routine tests without the need for a full-fledged cytometric laboratory. Guava Muse quantifies individual cells through ready-made mix-and-read kits and a step-by-step touch interface.

Request a quotation

Muse automatically guides the user from sample load to result, calculates thresholds and gates, and displays data in an applied format of a specific test. Available analysis of cell number and viability, apoptosis, cell cycle, caspases, mitochondrial potential, oxidative stress, autophagy, immunological markers and Two open modules allow you to perform your own two-color experiments.

Laser microcapillary system with analysis of up to 3 cell parameters: working range of cell sizes 2-60 μm, recommended concentration of 10,000-500,000 cells / ml; Suspension and adhesive cells, primary cultures and cell lines are supported; single-tube loading, analysis time less than 2 minutes per sample, direct absolute count; The user sets the sample size and the number of cells to be counted. The base area is about 200 x 250 mm, the data processing is done on the built-in touch interface with export of graphs, CSV and source files.

Ease of use

  • Touch interface conducts from sample loading to result without manual gate
  • Ready mix-and-read kits reduce sample preparation and analysis time
  • Single-tube loading, result in less than 2 minutes

Analysis opportunities

  • More than 20 ready-made Muse sets: counting and viability, apoptosis, cell cycle, DNA damage, autophagy, oxidative stress, immunology
  • 2 open modules (yellow and red channels) for own two-color experiments
  • Works with suspension and adhesive cells, primary cultures and cell lines

Data data

  • Absolute counting of cells without counting particles
  • Export of graphics, CSV and source files via USB

Technical specifications

ParameterGuava Muse
Number of cellular parameters3
Cell diameter2-60 μm
Concentration range10,000–500,000 cells/ml
Loading formatsingle-tube, less than 2 minutes per test
Cell typessuspension and adhesive, primary cultures and lines

Construction and data

ParameterGuava Muse
Dimensions (base area)≈200×250 mm (8×10 inches)
Export of dataUSB: graphics, CSV, source files
Open modules2 (yellow and red channels) for own 2-color experiments