Micro Solutions / Life Science
New generation Aurora: automation, feed speeds up to 200 μl/min and instrument harmonization

New generation Aurora: automation, feed speeds up to 200 μl/min and instrument harmonization
Full Spectrum Profiling for High-Term Laboratories
Cytek Aurora Evo is a next-generation spectral flow cytometer for high-parameter cell analysis, automated research and high-load laboratories. The platform develops Full Spectrum Profiling and preserves the portability of Aurora ecosystem panels.
The system records the full spectrum of each fluorochrome and performs spectral separation of signals, allowing you to build complex multicolor panels without constantly reconfiguring optical filters. Aurora Evo supports test tubes and microplates, accelerated sample delivery, standardized configuration and harmonization of instruments. The extended light scattering range allows for the analysis of both small particles and large cells in a single protocol.
The official Aurora Evo card is configured with up to 5 lasers and contains up to 64 fluorescent detectors. The maximum reported sample rate is up to 200 μl/min when working with test tubes and microplates. The platform uses Full Spectrum Profiling technology, automated quality control and SpectroFlo for control. The specific configuration of lasers, channels, loader and automation is selected according to the official technical specification of the manufacturer.
fluorescent detector
events/s (max.)
96-hole plate
μl/min, max. feed rate
64.5 × 61.0 × 60.0 cm
| Lasers | 488 nm (50 mW) + 640 nm (80 mW) 405 nm (100 mW) + 488 nm (50 mW) + 640 nm (80 mW) 405 nm (100 mW) + 488 nm (50 mW) + 561 nm (50 mW) + 640 nm (80 mW) 355 nm (20 mW) + 405 nm (100 mW) + 488 nm (50 mW) + 561 nm (50 mW) + 640 nm (80 mW) |
|---|---|
| Fluorescent channels | 22 (Blue+Red) 38 (Violet+Blue+Red) 48 (+ Yellow-Green) 64 (+ UV) |
| Detection range | 498–829 nm 420–829 nm 420–829 nm 365–829 nm |
| Nominal speed of registration | up to 35,000 events/s |
|---|---|
| Maximum speed of registration | up to 65,000 events/s |
| Sensitivity (MESF) | FITC ≤5, PE ≤4, APC ≤3, Pacific Blue ≤4 |
| Linearity | FITC R²≥0,995 / PE R²≥0,995 |
| Sample rate | 15/30/60/100/200 μl/min (Low/Medium/High/Ultra/Max) |
| Pipeline-sampling | standard mode ≤0.3%; low speed mode ≤0.1% |
| Sample format | 12×75 mm tubes; 96, 96 deep-well, 384; 40-tube tripod |
|---|---|
| Speed of loader | 24 min on 96-well microplate in high-performance mode |
| Dimensions | 64.5 × 61.0 × 60.0 cm |
| Weight | 95 kg (5-laser configuration) |
| Power supply | 100–140 V, 15 A or 200–250 V, 10 A; heat generation 500 W |
| Computer | Intel Core i5-13500 or analogue, 64 GB of RAM, SSD 1 TB + 2 TB, monitor 32" 4K UHD |
Selection of fluorochromes for device configuration
Automated and manual design of multicolor panels
Creating SpectroFlo experiments remotely, outside the instrument