Cytek
Desktop flow cytometer Amnis CellStream
Highly sensitive cell and small particle detection: MESF <5 for PE, up to 20,000 cells/s
A highly sensitive desktop flow cytometer for cells, extracellular vesicles and other small particles. Amnis CellStream offers a flexible configuration of up to seven lasers and an extended dynamic range in a compact system with an autosampler.
Request a quotationTDI-CCD architecture records the intensity of signals with high sensitivity, and the event gallery allows you to see the passage of objects in real time and monitor the quality of the experiment. It is intended for multiparameter single-cell analysis, immunophenotyping, small-particle studies and high-throughput processing of tubes or 96-well plates. CellStream is not a full-fledged visualizing cytometer: it provides three morphological parameters, not microscopic images of thousands of features.
From 1 to 7 lasers: 375, 405, 488, 532, 561, 642 and 730 nm; up to 22 channels, including 20 fluorescent, FSC and SSC. MESF sensitivity is less than 10 for FITC and less than 5 for PE, CV is less than 3%; speed up to 20,000 cells / s, expenditures of 3.66 and 14.64 μl / min FSC threshold less than 300 nm and SSC less than 200 nm, dynamic range 7 decades. one tube and 96-well plate; dimensions 440 x 625 x 495 mm.
Sensitivity and detection
- TDI-CCD single chamber detector architecture provides high sensitivity to small particles instead of a set of PEUs
- Low MESF values (<10 FITC, <5 PE) allow low concentration fluorophores to be detected
- Real-time Event Gallery supports visual quality control and error analysis
Flexibility of configuration
- 1 to 7 lasers (375, 405, 488, 532, 561, 642, 730 nm), upgrades are performed directly in the laboratory.
- Up to 22 detection channels, including 20 fluorescent plus FSC and SSC
- Work with a single test tube or 96-well microplate; supported absolute cell counting
Software
- 21 CFR Part 11 Compliance Tools for Electronic Records and Signatures
- Automatic daily calibration of the device
- CellStream does not form microscopic images of cells – the camera gives three morphological parameters (area, aspect ratio, maximum brightness of the pixel), unlike the full visualizing cytometry of FlowSight and ImageStreamX.
Optics and detection
| Parameter | Basic system (488 nm) | 4-laser system (405/488/561/642 nm) |
|---|---|---|
| Lasers complete | 488 nm (200 mW) | 405, 488, 561, 642 nm |
| Available lasers (upgrade) | 375, 405, 488, 532, 561, 642, 730 nm – up to 7 lasers in total | |
| Number of channels | up to 22 (20 fluorescent + FSC + SSC) |
Sensitivity and productivity
| Parameter | Basic system (488 nm) | 4-laser system (405/488/561/642 nm) |
|---|---|---|
| Sensitivity (MESF) | FITC <10, PE <5 | |
| CV (precision) | <3% (by CEN pellets) | |
| Speed of registration | up to 20,000 cells/s | |
| Flow speed | 3.66 μl/min (high sensitivity) / 14.64 μl/min (high speed) | |
| Dispersion authorization | FSC – particles from 300 nm; SSC – particles from 200 nm | |
| Dynamic range | 7 orders | |
| Morphological parameters (camera) | 3: area, aspect ratio, maximum brightness of the pixel |
Test and construction
| Parameter | Basic system (488 nm) | 4-laser system (405/488/561/642 nm) |
|---|---|---|
| Sampling formats | one test tube or 96-well microplate; absolute cell counting supported | |
| Dimensions | 440 x 625 x 495 mm | |
| Modernization | field upgrade of lasers directly in the laboratory |