Localization of individual molecules with a resolution of better than 20 nm - in 3D and with multiplex labeling

Localization of individual molecules with a resolution of better than 20 nm - in 3D and with multiplex labeling
SMLM workstation for STORM, PALM and PAINT with bi-plane detection and SRX software
Compact multimodal SMLM platform for quantitative 3D ultra-resolving imaging of cells and tissues.
Vutara VXL localizes individual molecules by STORM, PALM, PAINT and SPT methods, simultaneously registering two focal plans. SRX leads the user from calibration and shooting to 3D reconstruction and quantitative analysis; optional PlexFlo microfluidics supports serial multiplex labeling.
Declared lateral resolution better than 20 nm and axial 50 nm for bi-plane detection. Field of view is 50×50 μm for 3D SMLM and 200×200 μm for widefield or multiplex localization shooting; supported up to five consecutive colors, 60×/NA 1.3 objective and a typical imaging depth of more than 50 μm depending on the sample.
lateralization
axial, biplane
lineage
depth
compact workstation SMLM
clusters, colocalization, distributions
| SMLM Permission | better than 20 nm by XY; 50 nm by Z (Biplane) |
|---|---|
| Multiplane survey | 2 focal planes at the same time, the difference in depth of 1 μm; more - in the Z-stack mode |
| Depth of visualization | >50 μm typical, depending on the sample |
| Field of vision | 50 × 50 μm – SMLM and 3D localization; 200 × 200 μm – multiplex localization and wide field; more – crosslinking tiles |
| Excitation lasers | 405 nm 120 mW; 555 nm 2000 mW; 638 nm 1200 mW; optionally 488 nm 2000 mW and 750 nm 1500 mW |
|---|---|
| Multicolor photography | Up to 5 colors sequentially; 2 colors simultaneously with two cameras (optional) |
| Camera. | sCMOS Orca Flash 4.0 V3; optional Orca Fusion BT |
| Objective | 60×, NA 1.3, silicone immersion, working distance 0.3 mm, cover glass #1.5H |
| Regimes | SMLM, broadfield localization, epifluorescence, passing light |
| XY-table | stroke 100 × 50 mm, optical encoder with a resolution of 1 nm |
|---|---|
| Focus stability | drift <30 nm in 10 minutes; correction of XY drift after shooting |
| Software | SRX: shooting, 3D localization of measured PSF, particle tracking, statistical analysis, visualization |
|---|---|
| Microfluidic PlexFlo | 15 samples + buffer, tanks 2 ml; or 96 samples + buffer |
| Incubation | Control of temperature, CO2 and humidity for living cells (optional) |
Sequential multiplex tagging and washing in shooting cycles
Controlling Temperature, CO2 and Humidity for Living Cells
Expansion of fluorophores
Alternative sCMOS camera; second camera for simultaneous two-color shooting
Storage of large localization data sets