Microscope of Luxendo TruLive3D Imager

Bruker

Microscope of Luxendo TruLive3D Imager

Long-term 3D photography of hundreds of organelles and spheroids: up to six experimental conditions in one run

Inverted light-sheet microscope for long-term 3D visualization of living organoids, spheroids and embryos.

Request a quotation

Bilateral lighting and bottom detection reduce shading, and a controlled environment supports long-term experiments. The system works with hundreds of samples and up to six experimental conditions in a single launch.

The architecture includes two-way lighting, single-lens detection, piezo-crawler positioning and optional photo manipulation. The data processing kit includes 256 GB of RAM, 8×4 TB local storage RAID 0 and GeForce RTX 3070 GPU class.

Image quality

  • Bilateral lighting and detection with one lens from the bottom minimizes shading
  • Acoustic-controlled TAG lenses form a uniform light sheet and reduce axial stretching
  • Dual-destriping removes artifacts
  • Resolution up to 255 nm in XY plane for subcellular structures

Throughput

  • Simultaneous dual-channel shooting with two sCMOS cameras Orca Flash 4.0 V3
  • Extended holder for hundreds of samples
  • TruLive3D Dish series allows you to compare up to six conditions in one experiment

Live samples

  • Temperature control of 20-37 °C, CO2, O2, N2 and humidity for multi-day experiments
  • Sterile ready-made dishes make it easier to install samples
  • Pseudo-light field for finding a sample and monitoring its condition
  • Optional module of photomanipulation: ablation, optogenetics, FRAP

Optics

ParameterTruLive3D Imager
Objects of detectionNikon CFI APO LWD 25× 1,1 NA; Olympus XLUMPLFLN 16× 0,8 NA
IncreaseNikon: 12,5×, 25×, 37,5×, 50×; Olympus: 8×, 16×, 24×, 32×
Pixel size130–813 nm depending on the lens and tube lens
Field of vision266-1664 μm
Permission XY255 nm
Chromatic correction440–660 nm; motorized set of 90/10/1% ND filters

Detection

ParameterTruLive3D Imager
Cameras2 sCMOS Hamamatsu Orca Flash 4.0 V3
Quantum efficiencyup to 82% at 560 nm
Speed>80 fps with full frame 2048×2048

Samples and environment

ParameterTruLive3D Imager
Sample holder75 mm, two compartments, three disposable dishes; FEP film
Table move66 x 3 x 3 mm, piezo-kruller
Climate control20–37 °C; CO2, O2, N2; humidity

Data processing workstation

ParameterTruLive3D Imager
Processor/RAMIntel, 2×8 cores; 256GB
Warehouse8 x 4 TB, RAID 0
Video cardGeForce RTX 3070
Network10 Gbps Ethernet