Kino optical in vivo imaging system

Personal BLI/FLI imaging: up to three mice per shot on a laboratory table

Kino optical in vivo imaging system

Product overview

Personal BLI/FLI imaging: up to three mice per shot on a laboratory table

Spectral Instruments Imaging compact system with LED excitation and Aura software

BLI/FLI personal desktop system for small research groups and longitudinal experiments.

Kino captures bioluminescent and fluorescent images of up to three mice, microplates and other samples, and a compact camera, heated platform, LED excitation and Aura software enable a quick transition from experiment to quantitative output.

Capacity - 3 mice, maximum field of view - 13×13 cm Supported 10 wavelengths of LED-excitation and 5 emission filters; CCD-camera has absolute solid-state cooling to -90 ° C. X-ray channel in Kino is not provided.

Key figures

3

mouse-to-cap

13×13 cm

field

−90 °C

air-cooling

BLI · FLI

two-modalities

Applications

Models and configurations

Product details

Compact desktop system

56 × 66 × 122 cm

Quantitative results in Aura

calibration traceable to NIST

Sensitivity and quality of data

For small groups

Convenience and reliability

Modality and capacity

Visualization techniquesBioluminescence (BLI), fluorescence (FLI)
X-raynot provided
Capacityup to 3 mice
Maximum optical field of view13 × 13 cm
Visualization platform50x34 cm, heated 20-40 °C
Gas anesthesiaport-in

Camera.

SensorCCD 0.5" with backlight, Grade 1 plus
Sensor resolution1024 × 1024 pixels
Sensor size13 x 13 mm
Cooling-90 °C, solid state, air
Quantum efficiency>85% in the 500–700 nm range; >35% in the 700–900 nm range
Dark current.<100 e−/s/cm2
binning1×1, 2×2, 4×4, 8×8
Objective50 mm, aperture f/1.2–f/16
Minimum recorded brightness59 photons/s/cm2/sp

fluorescence

LED-excitation10 wavelengths: 430, 465, 500, 535, 570, 605, 640, 675, 710, 745 nm
Emission filters5 filters to choose from 20 standard (490–870 nm)
LED resource100,000 hrs

General.

Dimensions (E × G × B)56 × 66 × 122 cm
Calibrationabsolute, traceable to NIST; factory
SetPC, monitor, Aura software

Options

Light-tight access port

Connecting external systems to the camera; installed at the site of operation

Additional emission filters

Replacement by an operator from a standard set of 490-870 nm, custom-made