Micro Solutions Life ScienceRU

Micro Solutions / Life Science

SafeMate EZ Biological Safety Room

Class II type A2 with electric glass drive and optional gas and vacuum cranes

SafeMate EZ Biological Safety Room

Product overview

Class II type A2 with electric glass drive and optional gas and vacuum cranes

two versions in the width of the working area - 1.2 and 1.8 m, with a UV-C lamp in the kit

The SafeMate EZ is an A2-class BioAir II biosafety cabinet for everyday work with biomaterials and cell cultures. The front-glass electric drive, a fully stainless work chamber, and an ergonomic V-shaped input grille combine operator, product, and environmental protection with the convenience of routine procedures.

The cabinet forms a vertical laminar flow and a controlled air barrier, and HEPA filtering reduces the risk of cross-contamination. The flow rates are displayed in real time; the system monitors the correct position of the front window. The 5° tilted work area facilitates access, the electric glass makes it easier to open and the front window is not easily accessible. The steel chamber and work surface are designed for regular cleaning, the design is compatible with VHP decontamination, and the UV-C lamp is standard.

Performances: 1.2 and 1.8. Power - 220-240 V, 50/60 Hz; power consumption of the fan and lighting - 465 and 774 W. Dimensions without support - 1380×795×1450 and 1990×795×1450 mm; working area - 1230×600×700 and 1840×600×700 mm; weight - 256 and 360 kg. Filters H14 EN 1822-1, global efficiency MPPS - 99.995. Sound level - <56 and <60 dB(A), vibration <0.0005 mm RMS. Two auxiliary outlets; gas, air and vacuum service valves are available as options. EN 12469 is declared by the manufacturer.

Key figures

II·A2

biosecurity

H14

filters, MPPS 99.995 percent

ISO 5

cleanliness

VHP

Compatible with H2O2 vapor decontamination

Applications

Models and configurations

Product details

SafeMate EZ Biosafety Clothing

front-glass

Work area and controls

V-shaped input grille, service cranes

Protection and control

Ease of operation

Flexible configuration

Throughput

Class and type of protectionClass II, type A2
Laminar flow rate0.33–0.40 m/s
Speed of the air barrier entrance0.53 m/s ± 10%
Exhaust air flow480 m3/h ± 10%
600 m3/h ± 10%
Class of cleanliness of the working areaISO 5 according to EN 14644-1

Filtration and protection

Class of filter efficiencyH14 according to EN 1822-1
Global efficiency of MPPS99,995%
Frontal aperture protection coefficient (Apf)≥1,0×10⁵
Passage of UV-C through glass98%

Dimensions and conditions of use

Dimensions without support (D×G×B)1380 × 795 x 1450 mm
1990 × 795×1450 mm
Working area (DxGxV)1230×600×700 mm
1840×600×700 mm
Weight256 kg
360 kg
Sound level<56 dB(A)
<60 dB(A)
Vibration.<0.005 mm RMS
Power supply220–240 V, 50/60 Hz
Power consumption (fan and light)465 W
774 W.

Workplace configuration

Box cabinet (AC10000)

2 drawers on wheels under the cabinet

Support rack (AS1L410 / AS1L610)

Adjustable height rack 730-890 mm

Wheel kit (AZ1L010)

Wheelbase with a fixing support

Ipbar bars (AP1K604 / AP1K606)

10 Hooks for Infusion Systems

Armrests (AZ1H613)

Additional armrests to the V-shaped grille

Extract and additional filtration

Active extraction kit (AZ1H124 / AZ1H126)

Connection to an external exhaust system with an adapter for a carbon filter

Additional carbon filter (CP62000/CP66000)

Installs with an active extract adapter for working with volatile substances

Passive adapter kit (AZ1H204 / AZ1H206)

Connection to the hood outlet fan

Extract umbrella thimble (AZ1H304 / AZ1H306)

Open exhaust adapter for remote fan

Related equipment types

Related products

Classification

Product images

Documents

Manufacturer sources