Micro Solutions

Analytical solutions for your laboratory

RU
The cabinet for the preparation of cytotoxic drugs SafeMate Cyto

BioAir

The cabinet for the preparation of cytotoxic drugs SafeMate Cyto

Class II cabinet with three-stage HEPA filtering and replacement of the lower filter according to bag-in / bag-out scheme

SafeMate Cyto is a Class II BioAir biosafety cabinet for preparing and restoring cytotoxic and anticancer drugs. Three-stage HEPA filtration and safe bag-in/bag-out replacement of the bottom filter protect the operator, product, environment and service personnel.

Request a quotation

The cabinet creates a downward unidirectional flow and a controlled front barrier, continuously monitoring the exhaust volume, the condition of the filters and the position of the electric glass. In addition to the main recirculation and extract filters, under the working surface is a tertiary H14, through which 100% of the recycled air passes. The microprocessor provides self-calibration, start purge, multi-level alarms, filter life control and semi-automatic fumigation cycle. The camera and sectional work surface are made of AISI 304.

SafeMate Cyto models 1.2 and 1.8. the Match DIN 12980 and EN 12469:2000 declared by the manufacturer. Power - 230 V, 50 Hz; power - 400 and 750 W. Dimensions - 1380×846(795)×2220 and 1990×846(795)×2220 mm; working area - 1230×600×700 and 1840×600×700 mm; weight - 340 and 450 kg. Working front opening - 195 mm, maximum - 440 mm. approximately 440 and 650 m3/h; frontal speed ≥0.5 m/s; 25 air exchanges per minute at 30/70 extraction/recycling ratio. Three HEPA H14 stages, efficiency >99.995% MPPS according to EN 1822-1. Illumination >750 lux, noise <65 dB(A), two internal outlets.

Four levels of protection

  • Operator protection – frontal barrier with high aperture protection coefficient, as in a conventional biosafety cabinet
  • Environmental protection – double stage of HEPA H14 in the exhaust tract
  • Product protection and transfer between products – downward unidirectional recirculating flow
  • Service Personnel Protection – Tertiary HEPA H14 under the work surface, replaced by bag-in/bag-out protocol according to KTA 3601

Monitoring and alarm

  • Microprocessor with a volumetric sensor controls exhaust air flow
  • Automatic maintenance of specified flow volumes, constant monitoring of HEPA filters resource
  • Multi-level alarms with redundancy function in low flow or incorrect position of glass
  • Large screen with high resolution displays operating parameters

Maintenance and construction

  • Replacement of the tertiary filter - from the front, without breaking the isolation of the working area
  • Sloping front and back wall for easy access
  • Camera and sectional work surface from AISI 304
  • Electric sealed front glass with touch control

Protection and productivity

Parameter1.21.8
Protection classclass
Frontal barrier speed≥ 0.5 m/s
Volume of hoods≈440 m3/h≈650 m3/h
Ratio of extraction and recycling30/70 at 25 air exchanges per minute
Working frontal opening195 mm (maximum 440 mm)

Filtration

Parameter1.21.8
Steps of HEPA filtrationthree-step H14
Efficiency by MPPS>99.995% according to EN 1822-1

Dimensions and conditions of use

Parameter1.21.8
Dimensions (D×G×V)1380 × 846(795) x 2220 mm1990 × 846 (795) × 2220 mm
Working area (DxGxV)1230×600×700 mm1840×600×700 mm
Weight340 kg450 kg
Lighting>750 lux
Sound level<65 dB(A)
Power supply230 V, 50 Hz
Power consumption400 W.750 W.
Internal outlets2