140 l.
usefulness
Micro Solutions / Life Science
Direct heating incubator for 140 liters of usable volume with automatic decontamination at 125 °C

Direct heating incubator for 140 liters of usable volume with automatic decontamination at 125 °C
Four independent heating circuits and CO2 infrared sensor for stable cell cultures
SafeGrow PRO is a direct-heating BioAir CO2 incubator for stable cell and tissue culture, including primary and stem cells, hybridomas and ART processes. The 140-liter camera combines precise environmental control, convenient cleaning and automatic high-temperature decontamination.
Four independently controlled direct heating circuits and seven temperature sensors maintain uniformity on the six sides of the chamber without an internal fan. Solid state IR sensor measures CO2 regardless of humidity and supports AutoZero. Humidity is created passively by a removable stainless steel pallet. Seamless A large-angle, electropolished camera and a fully removable shelf system make cleaning easy: a programmable cycle heats the camera to 125°C, a log saves 500 events, and an RS-232 allows you to transmit parameters and alarms to an external monitoring system.
Total/useful volume - 188.6/140 L. Operating temperature range - 10–50 °C, not less than 1 °C above room; regulation and accuracy - ±0.1 °C, declared uniformity - about ±0.3 °C, recovery after a 15-second door opening - up to 5 minutes CO2 range - 0.5–20% increments of 0.1%; regulation - ±0.1%, accuracy - ±0.2% at a rate of 5%, recovery - up to 5 minutes. Humidity - up to 95% RH. Decontamination: 125 ° C, exposure 4 hours, full cycle 10.5-13.5 hours. Camera - 530×690×500 mm, external dimensions - 680×896×746 mm, weight - 102 kg. Four shelves 510×455 mm, area of each - 0.23 m2. Power - 220-240 V, 50/60 Hz; installed power - 1.5 kW, maintenance 37 ° C - <0.1 kW.
usefulness
temperature-precision
high-temperature decontamination
CO2 sensor independent of humidity
direct heating, volume 188.6/140 l
Seamless electropolished camera AISI 304
| Total/Useful volume | 188.6/140 l |
|---|---|
| Internal dimensions of the chamber | 530×690×500 mm |
| Number of shelves | 4, size 510×455 mm, area 0.23 m2 each |
| Temperature range | 10–50 °C (at least 1 °C above room) |
|---|---|
| Accuracy of temperature control | ±0,1 °C |
| Temperature uniformity | about ±0.3 °C |
| CO2 range | 0.5–20 percent increments of 0.1% |
| Precision of CO2 | ±0.2% at 5% |
| Humidity | up to 95% RH |
| Decontamination temperature | 125 °C, exposure 4 hours |
|---|---|
| Complete decontamination cycle | 10.5-13.5 hours |
| Dimensions (WxVxG) | 680×896×746 mm |
| Weight | 102 kg |
| Power supply | 220–240 V, 50/60 Hz |
| Installed capacity | 1.5 kW |
| Consumption while maintaining 37 °C | <0.1 kW |
Base with wheels and intermediate plate for installing two incubators on top of each other
A sectional interior door instead of one solid one
Alternative to solid shelves for better circulation
Filtration of the CO2 supplied gas
Consumable for the autocalibration function of the CO2 sensor
Verification gas for calibration of the CO2 sensor
Floor rack under the incubator