PCR box Aura PCR

BioAir

PCR box Aura PCR

Passive boxing with UV-C neutralization of DNA between PCR productions, without fan and laminar flow

The Aura PCR is BioAir's compact passive box to prepare samples and reaction mixtures before amplification. A closed working chamber with UV-C decontamination helps reduce the risk of DNA transfer between PCR settings without taking up space with ventilation equipment.

Request a quotation

Once the work is complete, the operator closes the three-section front glass and starts a specified UV-C cycle. Micro-switches allow ultraviolet lamps to operate only when the glass is closed; at the end of the cycle, the timer turns off the UV and puts the box into working mode with white LED lighting. The glass case delays more than 98% of UV radiation. The inner folding shelf increases the usable space, and the plastic countertop is resistant to laboratory reagents, the cabinet has no fan and does not create laminar flow.

Passive unventilated design, code PC20100. Power - 220-230 V, 50/60 Hz; power consumption - 100 W. Lighting - two LED lamps of 7 W, > 600 lux; UV-C - three T8 lamps of 15 W, peak 253.7 nm, resource 8000 hours, surface power density of one lamp at a distance of 1 m - 49 μW / cm2. UV-C timer - up to 60 minutes in increments of 1 minute and The dimensions are 650×545×730 mm, the working area is 550×470×570 mm, the maximum opening is 555×430 mm, the weight is 41 kg. Glass is tempered safe, 6 mm; the working surface is polyethylene.

Blocking DNA transfer

  • After the work is completed, the operator closes the three-section front glass and starts the specified UV-C cycle.
  • Microswitches allow the operation of UV lamps only when the glass is closed
  • At the end of the cycle, the timer turns off UV-C and puts the box into working mode with white LED lighting.
  • Glass enclosure delays more than 98% of UV radiation, protecting staff

ergonomics

  • Internal folding glass shelf increases usable space
  • The working surface of polyethylene is resistant to laboratory reagents
  • Lack of fan and laminar flow - compact unventilated construction

Controls

  • UV-C digital timer – up to 60 minutes in 1 minute increments and last setup memory
  • LED lighting is turned on automatically when the glass is opened or at the end of the UV cycle.

Design

ParameterAura PCR
Typepassive, unventilated boxing
Dimensions (W×D×H)650×545×730 mm
Working area (WxGxV)550×470×570 mm
Maximum opening555 x 430 mm
Weight41 kg
Glass.tempered safety, 6 mm
Working surfacepolyethylene

Lighting and UV-C

ParameterAura PCR
LED lighting2 lamps of 7 W, >600 lux
UV-C lamps3 T8 lamps at 15W, peak 253.7 nm
Resource UV-C lamps8,000 h
Power density of UV-C per 1 m49 μW/cm2
Timer UV-Cup to 60 minutes in 1 minute increments

Power supply

ParameterAura PCR
Power supply220–230 V, 50/60 Hz
Power consumption100 W.