
Berthold
Microvolume spectrophotometer Colibri+ LB 916
Measurement of DNA, RNA and protein in less than 3 seconds from a sample of 1 μl
Colibri+ LB 916 is a compact microvolume UV/VIS spectrophotometer for rapid assessment of the concentration and purity of DNA, RNA and proteins from a sample of 1 μl.
Request a quotationMeasurement takes less than 3 seconds and is performed autonomously through a 7-inch touch screen. Pre-installed protocols cover nucleic acids, A280 protein, Bradford, BCA and Lowry methods, OD600 and custom UV/VIS methods. Sample Guide Light backlight helps to pin the droplet and spot bubbles, and hydrophobic measuring The surface and the depreciable arm support reproducible optical column formation. The Colibri+ C version additionally works with divets, supports kinetics, stirring and thermostating.
Minimum sample volume 1 μl; measurement time less than 3 s. Range for dsDNA 2–20,000 ng/μl, for BSA 0.06–600 mg/ml; optical path 0.5 and 0.05 mm. Source – pulsed xenon lamp, detector – CMOS 2048 elements. Spectral range 190–1000 nm, wavelength accuracy of 1 nm brochure, band 1.3 nm, spectral resolution of 1.5 nm, absorption range 0.04-400 A in terms of 10 mm Screen 7 inches, memory 32 GB, USB-A. Dimensions 206×333×166 mm, weight 3.5 kg; CE, RoHS. For Colibri+ C: ditch optically 0.1-10 mm, thermostating 37–45 °C and stirring 150–850 rpm.
Speed and accuracy
- Measurement takes less than 3 seconds, CV absorption less than 1%
- Determination range of 2–20,000 ng/μL for dsDNA and 0.06–600 mg/mL for BSA without manual dilution
- Two optical path options – 0.5 and 0.05 mm – for measuring highly concentrated samples
Comfort of work
- Autonomous: 7-inch touch screen, 32 GB of internal memory, computer not required
- Sample Guide Light backlight makes it easier to apply a drop and detect bubbles even in low light
- More than 500 user folders with password protection
Prepared methods
- Pre-established protocols for nucleic acids and protein with QC coefficients
- Bradford, BCA and Lowry protein methods, and OD600 for cell cultures
- The Colibri+ C version further supports cuvettes, kinetics, microchips and labeled protein
Measurement (microvolume)
| Parameter | Colibri+ |
|---|---|
| Sample size | 1 μl |
| Range of DtsDNA/BSA | 2–20,000 ng/μl; 0.06–600 mg/ml |
| Optical path length | 0.5 and 0.05 mm |
| Time of measurement | less than 3 |
| Accuracy/CV absorption | 3.0% (at 0.75 A by 300 nm); CV <1% |
Optics
| Parameter | Colibri+ |
|---|---|
| Light source | pulse-lamp |
| Detector | CMOS, 2048 elements |
| Spectral range | 190–1000 nm |
| Accuracy of wavelength/bandwidth | 1 nm; band 1.3 nm; resolution 1.5 nm |
| Absorption range (10 mm EQ) | 0,04–400 A |
General parameters
| Parameter | Colibri+ |
|---|---|
| Screen/memory | 7'' color touch; 32 GB |
| Interface. | USB Type A; Colibri+C – additional USB Type B |
| Dimensions | 206×333×166 mm |
| Weight | 3.5 kg |
| Power supply | 100–240 B AC/24 B DC, 2.08 A |
| Certification | CE, RoHS |
Cuvet module (Colibri+C)
| Parameter | Colibri+ |
|---|---|
| cuvettes | 10/5/2/1/0.5/0.2/0.125/0.1 mm, quartz or plastic |
| Measurement range | 0,002–1,5 A |
| temperature control/mixing | 37–45 °C; 1–8 speeds (150–850 rpm) |
| Range in the ditch | dsDNA 0.3–75 ng/μl; BSA 0.003–2.25 mg/ml |
