Analytik Jena
ISP-MS spectrometer PlasmaQuant MS Q
High-performance ISP-MS for routine toxicology: up to 80 samples per hour
PlasmaQuant MS Q is a versatile high-performance ISP-MS for routine control and clinical toxicology studies, where low detection limits and a large sample series are important.
Request a quotationThe model is optimized for rapid multi-element analysis with a wide dynamic range and effective interference removal in iCRC. High sensitivity allows you to reduce the integration time and increase the breeding of complex biological matrices, reducing contamination of the input system. determination of metals in whole blood, serum, plasma and urine, and for control of elemental impurities in pharmaceutical materials.
Declared sensitivity for 115In - 800 thousand IMP / s per μg / l, background at a mass of 5 AU - less than 0.7 IMP / s; analytical range in pulsed mode reaches 11 orders of magnitude. The series uses a four-channel pump 0-100 RPM, a sprayer 400 μl / min, a cooled to -15 ° C Scott camera and low-flow burner. performance of up to 80 samples per hour for the appropriate high-performance technique; the actual speed depends on the panel of elements and sample preparation.
Ion optics and separation
- ReflexION’s 90-degree reflective ion optics with three-dimensional ion beam focus separates sensitive components from a direct beam of photons and neutrals
- HD-quadrupole with a full mass range of 3-260 AU provides high resolution and low abundance sensitivity
- The all-digital AD Detection does not require regular cross-calibration, as is the case with analog-to-digital detectors.
Elimination of interference and stability
- The built-in helium and hydrogen iCRC reaction cell provides rapid and efficient suppression of molecular interferences.
- BOOST technology supports sensitivity in gas mode without degrading detection limits
- Interface cones are replaced in less than a minute without disassembly of the sample input system, which reduces downtime
Sampling and software
- The open layout of the input system simplifies access to the sprayer, camera and burner during everyday maintenance.
- ASpect MS software automates calibration and resolution tests
- Modules for aerosol dilution, work with pure organic solvents (Nitrox) and pairing with HPLC are available
Throughput
- The wide dynamic range in the detector pulse mode – 11 orders of magnitude – allows you to measure from ultratrace to main concentrations in one measurement.
- High sensitivity allows to reduce the integration time and increase the breeding of complex biological matrices
- The manufacturer brings the performance of up to 80 samples per hour for the appropriate high-performance technique.
Sensitivity and specificity of the model
| Parameter | PlasmaQuant MS Q |
|---|---|
| Sensitivity (115In) | 800,000 mp/s per μg/l |
| Background (mass 5 AU) | less than 0.7 mp/s |
| Dynamic range | 11 orders (pulse mode) |
| Throughput | Up to 80 samples / h (high-performance technique) |
| Purpose | routine control and clinical and toxicological studies |
Ion optics and detector
| Parameter | PlasmaQuant MS Q |
|---|---|
| Ion optics | ReflexION, 90° reflection, 3D focusing of the ion beam |
| quadrupole | HD-quadrupole 3 MHz, mass range 3-260 AU, min. fixation time 50 μs, scanning speed > 5000 AU / s |
| RF generator | solid-state, 27 MHz, plasma power 300-1600 W |
| Detector | All-digital AD Detection system |
Elimination of interference
| Parameter | PlasmaQuant MS Q |
|---|---|
| Reaction cell | iCRC (Integrated Collision Reaction Cell), He and H2 gases at the top of the skimmer cone |
| BOOST technology | maintains sensitivity in gas mode without loss of detection limits |
| Replacement of interface cones | less than 1 min without dismantling the sampling system |
Sampling system
| Parameter | PlasmaQuant MS Q |
|---|---|
| Peristaltic pump | four-channel, 0-100 rpm |
| Sprayer | concentric, 400 μl/min |
| Spray chamber | Scott's two-way chamber, Peltier cooling from room temperature to -15 °C |
| Burner. | low-consumption, solid, 2.4 mm injector, support for hot and cold plasma |