ISP-MS spectrometer PlasmaQuant MS Elite

Maximum sensitive ISP-MS series for ultratrace and isotope analysis

A general picture of the PlasmaQuant MS and MS Elite series, the execution and configuration depend on the model chosen.

Product overview

Maximum sensitive ISP-MS series for ultratrace and isotope analysis

with precision isotope ratios and laser ablation support (LA-ICP-MS)

PlasmaQuant MS Elite is the most sensitive research configuration of the series for ultratrace elemental analysis, isotope ratios, specialization and laser ablation techniques.

The system is focused on tasks that require maximum ion transfer, low background and precise separation of adjacent masses. The user can optimize the focus of ions for the target method; the short ion path helps to maintain the shape of fast transient signals during laser ablation and analysis of individual particles. Advanced research into biological, geological and high-purity materials.

The declared sensitivity for 115In is 1.5 million Imp/s per μg/L, the background at a mass of 5 AU is less than 1 Imp/s. For isotope relations, the manufacturer gives a precision of less than 0.06 % RSD for 10B/11B, less than 0.01 % for 87Sr/86Sr, less than 0.02 % for 206Pb/207Pb and less than 0.07 % for 235U/238U. The total hardware platform includes a pump of 0–100 RPM, 400 μl/min sprayer, cooled to -15 °C chamber and low-flow burner; inert and organic input kits are available.

Key figures

1 500 000

μg/L (115In)

<0,01 %

RSD 87Sr/86Sr

LA-ICP-MS

laser-abluation

Applications

Models and configurations

Product details

PlasmaQuant MS Elite

flagship research configuration

PlasmaQuant MS lineup

four-platform models

Ion optics and separation

Elimination of interference and stability

Sampling and software

Accuracy for research

Sensitivity and specificity of the model

Sensitivity (115In)1 500 000 IMP/s per μg/L
Background (mass 5 AU)less than 1 mp/s
Precision 10B/11Bless than 0.06% RSD
Precision 87Sr/86Srless than 0.01% RSD
Precision 206Pb/207Pbless than 0.02% of RSD
Precision of 235U/238Uless than 0.07% RSD
Purposeultratrace analysis, isotope relations, specialization, LA-ICP-MS

Ion optics and detector

Ion opticsReflexION, 90° reflection, 3D focusing of the ion beam
quadrupoleHD-quadrupole 3 MHz, mass range 3-260 AU, min. fixation time 50 μs, scanning speed > 5000 AU / s
RF generatorsolid-state, 27 MHz, plasma power 300-1600 W
DetectorAll-digital AD Detection system

Elimination of interference

Reaction celliCRC (Integrated Collision Reaction Cell), He and H2 gases at the top of the skimmer cone
BOOST technologymaintains sensitivity in gas mode without loss of detection limits
Replacement of interface conesless than 1 min without dismantling the sampling system

Sampling system

Peristaltic pumpfour-channel, 0-100 rpm
Sprayerconcentric, 400 μl/min
Spray chamberScott's two-way chamber, Peltier cooling from room temperature to -15 °C
Burner.low-consumption, solid, 2.4 mm injector, support for hot and cold plasma

Sample entry kits and consumables

Starter Kit PQMS AQUA

Standard sample entry kit for water samples

Starter Kit PQMS ORGANIC

Set for organic solvents and organic matrices

Starter Kit PQMS INERT Semicon

Inert corrosion-resistant PFA kit with platinum injector for semiconductor and high-purity tasks

Platinum interface cones

For petrochemical samples and aggressive matrices

Options and modules

Autosamplers

For high-performance automatic analysis of sample series

Aerosol breeding

Automatic dilution of aerosol samples for working with high-matric samples without manual dilution

Nitrox

Gas console for direct analysis of pure organic solvents

Clarity HPLC Software

Software module for interface with HPLC