ISP-MS spectrometer PlasmaQuant MS

Sustainable ISP-MS for high-matric samples: sensitivity of more than 500 thousand IMP / s per μg / l

A general picture of the PlasmaQuant MS and MS Elite series, the execution and configuration depend on the model chosen.

Product overview

Sustainable ISP-MS for high-matric samples: sensitivity of more than 500 thousand IMP / s per μg / l

for heavy metals in blood and urine, trace elements in hair, nails, products

PlasmaQuant MS is a compact ISP-MS for reliable multi-element analysis of complex and high-matrix samples, including biological fluids, food products and environmental samples.

The device combines stable plasma with 90-degree reflective ion optics, which separates sensitive components from a straight line of photons and neutral particles. the iCRC's built-in collision reaction cell helps suppress spectral interference, and the open layout simplifies access to the sample input system and daily maintenance. The model is focused on stable work with high mineralization matrices.

The declared sensitivity for 115In is more than 500 thousand IMP / s per μg / l, the background at a mass of 5 AU is less than 0.5 IMP / s. The total platform of the series includes a four-channel peristaltic pump 0-100 RPM, a concentric sprayer with a flow rate of 400 μl / min, a two-way Scott chamber with Peltier cooling from room temperature to −15 ° C and a single-piece. low-consumption burner with an injector of 2.4 mm The manufacturer indicates the consumption of plasma-forming argon about 10 l / min and stability for high-matrix samples.

Key figures

>500 000

μg/L (115In)

iCRC

elimination

−15 °C

spray-cooling

Applications

Models and configurations

Product details

PlasmaQuant MS

base model of the series for high-matric samples

PlasmaQuant MS lineup

four-platform models

Ion optics and separation

Elimination of interference and stability

Sampling and software

Sensitivity and specificity of the model

Sensitivity (115In)more than 500,000 IMP/s per μg/L
Background (mass 5 AU)less than 0.5 mp/s
Argon flow (plasma-forming)about 10 l/min
Purposestable characterization of high-matric samples

Ion optics and detector

Ion opticsReflexION, 90° reflection, 3D focusing of the ion beam
quadrupoleHD-quadrupole 3 MHz, mass range 3-260 AU, min. fixation time 50 μs, scanning speed > 5000 AU / s
RF generatorsolid-state, 27 MHz, plasma power 300-1600 W
DetectorAll-digital AD Detection system

Elimination of interference

Reaction celliCRC (Integrated Collision Reaction Cell), He and H2 gases at the top of the skimmer cone
BOOST technologymaintains sensitivity in gas mode without loss of detection limits
Replacement of interface conesless than 1 min without dismantling the sampling system

Sampling system

Peristaltic pumpfour-channel, 0-100 rpm
Sprayerconcentric, 400 μl/min
Spray chamberScott's two-way chamber, Peltier cooling from room temperature to -15 °C
Burner.low-consumption, solid, 2.4 mm injector, support for hot and cold plasma

Sample entry kits and consumables

Starter Kit PQMS AQUA

Standard sample entry kit for water samples

Starter Kit PQMS ORGANIC

Set for organic solvents and organic matrices

Starter Kit PQMS INERT Semicon

Inert corrosion-resistant PFA kit with platinum injector for semiconductor and high-purity tasks

Platinum interface cones

For petrochemical samples and aggressive matrices

Options and modules

Autosamplers

For high-performance automatic analysis of sample series

Aerosol breeding

Automatic dilution of aerosol samples for working with high-matric samples without manual dilution

Nitrox

Gas console for direct analysis of pure organic solvents

Clarity HPLC Software

Software module for interface with HPLC