Micro Solutions

Analytical solutions for your laboratory

RU
Rapid Bacteriology Analyzer ALFRED 60/AST

Alifax

Rapid Bacteriology Analyzer ALFRED 60/AST

Clinically significant antibiotic sensitivity within the work shift

ALFRED 60/AST is Alifax’s fully automated rapid bacteriology and phenotypic antibiotic sensitivity analyzer to produce clinically relevant results within the work shift.

Request a quotation

The system automates the workflow from putting a sample into a specialized broth to incubation, optical reading, building a growth curve and transmitting results. With branded reagents, rapid bacterial culture, residual antimicrobial activity test, clinical sensitivity determination (AST) and screening are performed. The laser light scattering method detects the replication of living bacteria and reduces the effects of cellular and salt interference in the original matrix.

Capacity: 60 samples. The design includes a refrigerated zone of reagents / samples, an inoculation carousel and an independent optical reading zone. Incubation and continuous monitoring are performed automatically, the software manages the protocols and transmits the results. For rapid uroscrination, the manufacturer indicates the result in about 3 The data on direct AST from positive hemocultures published on the official website show a median time of about 5-6.3 hours; the actual time depends on the method and the microorganism.

Automation of the process

  • Full automation from the introduction of a sample into a specialized broth to incubation, optical reading and transmission of the result
  • The laser light scattering method registers the replication of living bacteria, reducing the effect of cellular and salt interference

Clinical challenges

  • Rapid bacterial culture and residual antimicrobial activity test
  • Clinical Sensitivity Determination (AST) and Screening of Multi-Resistant Organisms
  • Rapid uroscrination - the result in about 3 hours

Design

  • Cooled zone of reagents and samples, inoculation carousel and independent optical reading zone
  • The software manages protocols and automatically transmits results.

Throughput

ParameterALFRED 60/AST
Capacity60 samples
Rapid uroscrinationresult in approximately 3 hours
Direct AST from positive hemoculturemedian time of 5-6.3 hours (depending on the method and the microorganism)

Design

ParameterALFRED 60/AST
Reagent/sample zonecoolable
Inoculationcarousel
Readingindependent optical zone, laser light scattering
Monitoringcontinuous